    Product Details:

    Place of Origin: China
    Brand Name: OFAN
    Certification: CE,UL,3C
    Model Number: LD133N-48D3-01

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: $10~30/pcs
    Packaging Details: 65*65*70
    Delivery Time: 5-8 word days
    Payment Terms: L/C, T/T
    Supply Ability: 10000pcs20days
    Contact Now
    Detailed Product Description
    Rated Voltage: 48V Rated Speed: 4000RPM
    Air Flow: 360m³/h Power: 38.4W
    Current: 0.8A Operation Voltage: 36-56V

    Resemble Ebm-past 133mm DC Centrifugal Fan With Fresh Air System Eqjipment Cooling

     

    Listed
    Model
    Rated
    Voltage
    Operation
    Voltage
    Rated
    Current
    Power Rated
    Speed
    Air
    Flow
    Air
    Flow
    Air
    pressure
    Noise
    Level
    Part NO. VDC VDC A W RPM m³/h CFM mmH2O dBA
    LD133N-48D3-00 48 36~56 1.3 62.4 4500 420 210 41.5 70
    LD133N-48D3-01 48 36~56 0.8 38.4 4000 360 185 36.8 65
    LD133N-24D3-0 24 16~28 1.6 38.4 4000 360 185 36.8

    65

     

     

     

     

     

     

     

     

     

    EC Motor – Principle 
    With an EC motor the electronic circuitry stands in lieu of the traditional mechanical commutation meaning the right amount is being supplied in the right direction at exactly the right time providing precise motor control.

    Permanent-magnet brushless DC motor within the rotor
    The stator is driven by electronic switches (which replace the Carbon brushes), controlled by a microcontroller.
    Electronic system (hall effect sensor or software is used to recognize the rotor position)
    AC operated (230Volts Single phase or 380/480Volts 3phase, 50/60Hz)

     

     

    Energy savings with EC fans
    Let’s assume a laminar flow workstation requiring 13200m³/h at 450Pa. This requires 4 off Ø315 backward curved fans. Now let us assume that this workstation operates for 50 weeks of the year and for 8 hours per day at full speed. During non working hours to maintain the work area, the fans are run at roughly half the airflow.

    AC fan 2800hrs @ 4 x 1.41kW = 5.64kW 15,792 kWh
    5600hrs @ 4 x 0.62kW = 2.48kW 13,888 kWh
    Total A 29,680 kWh
    EC fan 2800 hrs @ 4 x 1.04kW = 4.16kW 11,648 kWh
    5600 hrs @ 4 x 0.27kW = 1.08kW 6,048 kWh
    Total B 17,696 kWh
    A minus B 11,984kWh saved with the EC fan

     

     

    Why choose us? 
    1. We belongs to the factory, so price we can give is based on factory cost, not trading cost.
    2. We are sole International sales of the factory, we can help to control and protect the market of clients.
    3. We integrates different kinds of products for air management.
    4. We are independent of factory. This make us standing in the position of client instead of factories. It will solve your problem of communication with factory.

     

     

     

     

    Resemble Ebm-past 133mm DC Centrifugal Fan With Fresh Air System Eqjipment Cooling

     

     

    Contact Details
    Ofan Electric Co., Ltd

    Contact Person: walter

    Send your inquiry directly to us (0 / 3000)