Place of Origin: | China |
Brand Name: | OFAN |
Certification: | CE ROHS |
Model Number: | LD175C-230D3-00 |
Minimum Order Quantity: | 1 |
---|---|
Price: | negotiation |
Packaging Details: | Simple packing |
Supply Ability: | 10000PCS 15days |
Power Input: | 82W | Air Flow: | 660m³/h |
---|---|---|---|
Rated Speed: | 3650RPM | Nominal Voltage: | 220V |
Current Drwa: | 0.65A | Frequency: | 50/60HZ |
High Light: | industrial centrifugal blower,centrifugal fans and blowers |
Air Cleaning Unit EC Centrifugal Fans With Dust Proof Workshop Clean Room
EC Motor – Principle
With an EC motor the electronic circuitry stands in lieu of the traditional mechanical commutation meaning the right amount is being supplied in the right direction at exactly the right time providing precise motor control
Type |
Nominal voltage (VAC) |
Frequency (HZ) |
Speed |
Power imput (w) |
Current draw (A) |
Sound pressure (dB) |
Perm.amb.temp
|
LD175C-230D3-00 | 220 | 50/60 | 3650 | 82 | 0.65 | 68 | -25~+60 |
How does this affect energy efficiency?
1. Doubling the speed of a motor increases its power input by a factor of 8 so it’s very wasteful to run a fan faster than is required. If you can tailor the fan speed to match the demand, the potential for energy saving is huge. Even when compared to on/off operation, EC speed modulation is much more efficient.
2. EC fans can also contribute to increasing the overall efficiency of an application. In a cooling system for example, keeping the refrigerant pressure constant rather than having it rise and fall as fans switch on and off has been found to reduce the load on the compressor resulting in even greater energy saving.
3. If two motors are producing the same output but one has a greater power input then you can be sure that the surplus energy is being dissipated as heat. If an application is designed to remove heat then it will have to do extra work just to remove the heat produced by the fan motor itself, so EC fans will improve the efficiency of the whole system.
Compact configuration, convenient installation and credible running
Pressure high, airflow stable
Little noise, energy saving and highly active
Several speed rang, adapt to both frequency conversion and voltage transformation, speed changing active
if the fans doesn't work well, what shall I do ?
If happens within one year, we will take in charge of the maintenance, or send you a new machine freely.
If after one year, we will supply you the right parts to replace at low price.
What about delivery date?
Product can be sent to you within a week if there is stock after receiving deposit or 100% payment from customer. If there is no stock, the delivery date will be 15 to 30 days
Contact Person: walter
Tel: +8613760806200